STREAMLIGHT® Survivor CLASS
I, DIVISION 1 - Fast Charge and Steady Charge |
 |
| Battery |
Nickle-cadmium
4.8 Volt, 1.8 amp hour, sub-C; rechargeable up to
1,000 times. |
| Lamp |
2.1
Watt, 4.8 Volt |
| Material |
Flashlight
case is made from high impact, super tough nylon
and is "O" Ring sealed; unbreakable Lexan®
lens; two-position rotary switch is "O"
Ring sealed. |
| Color |
Orange
Yellow
|
Weight
(with battery) |
15.4
ounces |
| Dimensions |
6.88"(H)
x 3" (W) x 3.38" (D) |
| Run
Time |
Up
to 4.25 hours of continuous use between charges. |
| Candlepower* |
Up
to 15,000 pre-focused. |
| Special
Features |
One
hour 120V AC or 12V DC Fast Charge.
or
Ten hour 100V, 120V, 230V or 240V AC, or 12V DC
Steady Charge.
Spring loaded clip with built in attachment ring
works with belts and harnesses |
|
 |
STREAMLIGHT® Survivor CLASS
I, DIVISION 2 - Fast Charge and Steady Charge |
 |
| Battery |
Nickle-cadmium
4.8 Volt, 1.8 amp hour, sub-C; rechargeable up to
1,000 times. |
| Bulb |
5.5
watt, 4.8 Volt "black dot" xenon bulb
providing Smoke Cutter® optics. |
| Material |
Flashlight
case is made from high impact, super tough nylon
and is "O" Ring sealed; unbreakable Lexan®
lens; two-position rotary switch is "O"
Ring sealed. |
| Color |
Orange
Yellow
|
Weight
(with battery) |
15.4
ounces |
| Dimensions |
6.88"(H)
x 3" (W) x 3.38" (D) |
| Run
Time |
Up
to 1.7 hours of continuous use between charges. |
| Candlepower* |
Up
to 25,000 |
| Special
Features |
Same
charging features as Class I, Division 1 model.
Also Fast Charge and Steady Charge available in
"PiggyBack" charging unit, allowing
simultaneous charge of light and spare battery
pack. Hinged door and latch for quick battery
reload
|
|
 |
| |
*Maximum
Peak Beam Candlepower |
 |
For Survivor
(Division 1): Class I, Division 1, Groups C & D
Temperature Rating T3C; Class I, Division 2, Groups
A, B, C, D Temperature Rating T3C; Class II, Division
2, Groups F & G; Class III, Temperature Rating T6
For Survivor
(Division 2): Class I, Division 2, Groups A, B, C, D
Temperature Rating T2; Class II, Division 2, Groups
F & G; Class III, Temperature Rating T4
|
 |
For
Survivor (Division 2): Class I, Division 2, Groups A,
B, C, D Temperature Rating T2; Class II, Division 2, Groups
F & G; Class III, Temperature Rating T4 |
 |
Charger
Holder meets requirements of NFPA 1901-12-1.7 mounted
in any position |
 |
Meets
applicable European Community Directives |
| |
Lexan®
is a registered trademark of General Electric. |
|
|
|
|
|
|
|
|
|
|
|
| |